About this view

This batch detail page ties execution evidence, material genealogy, equipment fitness, in-process controls, and quality events into one release-focused view. Users can trace each unit operation against timestamps and investigate linked exceptions without leaving context. The panelized layout supports QA review by exception while preserving full evidence access. Next actions include closing residual issues and completing disposition-ready evidence checks.

Planned
2026-03-21 → 2026-03-28
Actual
2025-06-28 → 2024-11-09
Exceptions
19
Release Risk
medium
Step Timeline
StepStatusStartEndResult
Materials Consumed and Genealogy
LotMaterialStatusGenealogy
LOT-012288Povidone K30 Variant 6approvedOpen workbench
LOT-012289Talc Variant 6quarantineOpen workbench
LOT-012290Colloidal Silicon Dioxide Variant 6holdOpen workbench
LOT-012291Stearic Acid Variant 6rejectedOpen workbench
Equipment and Calibration
AssetStatusCalibration DueQualification
AST-01116 Metal Detector #117in-maintenance2025-09-12qualified
AST-01117 X-Ray Inspection #118out-of-service2025-09-19qualified
AST-01118 Leak Tester #119cleaning-required2025-03-26requalification-due
In-Process Controls and Pending Tests
ControlMeasuredSpecStatus
Exceptions and Deviations
ExceptionSeverityStatusDeviation
Material Discrepancymajorunder-reviewNot linked
Material Discrepancymajorunder-reviewdev-00073
Material Discrepancymajorunder-reviewNot linked
Material Discrepancymajorunder-reviewNot linked
Material Discrepancymajorunder-reviewNot linked
Material Discrepancymajorunder-reviewdev-01073
QA Review Checklist and Signatures
  • Step execution completeness verified with signed evidence.
  • All high-severity exceptions dispositioned or justified.
  • QC release tests reviewed and OOS investigations closed or dispositioned.
  • Final release signatory validated with segregation-of-duties check.
No release readiness record found.