About this view

This batch detail page ties execution evidence, material genealogy, equipment fitness, in-process controls, and quality events into one release-focused view. Users can trace each unit operation against timestamps and investigate linked exceptions without leaving context. The panelized layout supports QA review by exception while preserving full evidence access. Next actions include closing residual issues and completing disposition-ready evidence checks.

Planned
2025-03-21 → 2025-04-01
Actual
2024-03-01 → In progress
Exceptions
14
Release Risk
low
Step Timeline
StepStatusStartEndResult
Materials Consumed and Genealogy
LotMaterialStatusGenealogy
LOT-012936Methanol HPLC Grade Variant 7approvedOpen workbench
LOT-012937Hydrochloric Acid 37% Variant 7quarantineOpen workbench
LOT-012938Sodium Hydroxide Variant 7holdOpen workbench
LOT-012939Phosphoric Acid Variant 7rejectedOpen workbench
LOT-012940Active Pharmaceutical Ingredient A Variant 8expiredOpen workbench
LOT-012941Active Pharmaceutical Ingredient B Variant 8consumedOpen workbench
LOT-012942Active Pharmaceutical Ingredient C Variant 8in-processOpen workbench
LOT-012943Microcrystalline Cellulose Variant 8approvedOpen workbench
Equipment and Calibration
AssetStatusCalibration DueQualification
AST-01169 Filling Machine #170operational2026-04-30not-qualified
AST-01170 Visual Inspection System #171operational2025-02-18qualified
AST-01171 Weighing Balance #172in-calibration2025-05-11qualified
AST-01172 HPLC System #173in-maintenance2026-03-24qualified
AST-01173 UV-Vis Spectrophotometer #174out-of-service2024-07-28requalification-due
AST-01174 Karl Fischer Titrator #175cleaning-required2025-12-31not-qualified
AST-01175 Dissolution Tester #176operational2024-11-26qualified
In-Process Controls and Pending Tests
ControlMeasuredSpecStatus
Exceptions and Deviations
ExceptionSeverityStatusDeviation
System Errorminorunder-reviewNot linked
System Errorminorunder-reviewNot linked
System Errorminorunder-reviewNot linked
System Errorminorunder-reviewdev-00368
System Errorminorunder-reviewNot linked
System Errorminorunder-reviewdev-00868
QA Review Checklist and Signatures
  • Step execution completeness verified with signed evidence.
  • All high-severity exceptions dispositioned or justified.
  • QC release tests reviewed and OOS investigations closed or dispositioned.
  • Final release signatory validated with segregation-of-duties check.
Release Readiness: BT-020367
Score: 94
EBR completionComplete
Exceptions closedComplete
QC approvedComplete
Deviations dispositionedComplete
Calibration compliantComplete
Training confirmedOpen

Release review complete - all criteria met.

Disposition recommendation is simulated and requires QA Reviewer persona sign-off before final approval.