About this view

This batch detail page ties execution evidence, material genealogy, equipment fitness, in-process controls, and quality events into one release-focused view. Users can trace each unit operation against timestamps and investigate linked exceptions without leaving context. The panelized layout supports QA review by exception while preserving full evidence access. Next actions include closing residual issues and completing disposition-ready evidence checks.

Planned
2025-11-09 → 2025-11-20
Actual
2026-10-11 → In progress
Exceptions
20
Release Risk
low
Step Timeline
StepStatusStartEndResult
Materials Consumed and Genealogy
LotMaterialStatusGenealogy
LOT-012317Croscarmellose Sodium Variant 7holdOpen workbench
LOT-012318Povidone K30 Variant 7rejectedOpen workbench
LOT-012319Talc Variant 7expiredOpen workbench
LOT-012320Colloidal Silicon Dioxide Variant 7consumedOpen workbench
LOT-012321Stearic Acid Variant 7in-processOpen workbench
LOT-012322Titanium Dioxide Variant 7approvedOpen workbench
LOT-012323Polyethylene Glycol 400 Variant 7approvedOpen workbench
Equipment and Calibration
AssetStatusCalibration DueQualification
AST-01317 X-Ray Inspection #318operational2025-07-19qualified
AST-01318 Leak Tester #319in-calibration2026-02-08requalification-due
AST-01319 Torque Tester #320in-maintenance2026-03-01not-qualified
AST-01320 Granulator #321out-of-service2026-03-30qualified
AST-01321 Tablet Press #322cleaning-required2025-04-30qualified
AST-01322 Film Coater #323operational2025-04-11qualified
AST-01323 Capsule Filler #324operational2025-10-01requalification-due
In-Process Controls and Pending Tests
ControlMeasuredSpecStatus
Exceptions and Deviations
ExceptionSeverityStatusDeviation
Equipment Conflictmajorunder-reviewdev-00332
Equipment Conflictmajorunder-reviewNot linked
Equipment Conflictmajorunder-reviewNot linked
Equipment Conflictmajorunder-reviewNot linked
Equipment Conflictmajorunder-reviewNot linked
Equipment Conflictmajorunder-reviewdev-00832
QA Review Checklist and Signatures
  • Step execution completeness verified with signed evidence.
  • All high-severity exceptions dispositioned or justified.
  • QC release tests reviewed and OOS investigations closed or dispositioned.
  • Final release signatory validated with segregation-of-duties check.
Release Readiness: BT-020331
Score: 99
EBR completionComplete
Exceptions closedComplete
QC approvedComplete
Deviations dispositionedComplete
Calibration compliantComplete
Training confirmedOpen

Release review complete - all criteria met.

Disposition recommendation is simulated and requires QA Reviewer persona sign-off before final approval.