About this view

This batch detail page ties execution evidence, material genealogy, equipment fitness, in-process controls, and quality events into one release-focused view. Users can trace each unit operation against timestamps and investigate linked exceptions without leaving context. The panelized layout supports QA review by exception while preserving full evidence access. Next actions include closing residual issues and completing disposition-ready evidence checks.

Planned
2026-08-25 → 2026-08-29
Actual
Pending → In progress
Exceptions
15
Release Risk
medium
Step Timeline
StepStatusStartEndResult
Materials Consumed and Genealogy
LotMaterialStatusGenealogy
LOT-012790Active Pharmaceutical Ingredient A Variant 3approvedOpen workbench
LOT-012791Active Pharmaceutical Ingredient B Variant 3approvedOpen workbench
LOT-012792Active Pharmaceutical Ingredient C Variant 3approvedOpen workbench
LOT-012793Microcrystalline Cellulose Variant 3quarantineOpen workbench
LOT-012794Lactose Monohydrate Variant 3holdOpen workbench
LOT-012795Hydroxypropyl Methylcellulose Variant 3rejectedOpen workbench
LOT-012796Magnesium Stearate Variant 3expiredOpen workbench
LOT-012797Croscarmellose Sodium Variant 3consumedOpen workbench
LOT-012798Povidone K30 Variant 3in-processOpen workbench
LOT-012799Talc Variant 3approvedOpen workbench
Equipment and Calibration
AssetStatusCalibration DueQualification
AST-01232 Cartoning Machine #233operational2024-10-30qualified
AST-01233 Blister Packer #234operational2026-03-07requalification-due
AST-01234 Shrink Wrapper #235in-calibration2025-09-11not-qualified
AST-01235 Checkweigher #236in-maintenance2024-12-07qualified
AST-01236 Metal Detector #237out-of-service2026-05-30qualified
AST-01237 X-Ray Inspection #238cleaning-required2025-01-14qualified
AST-01238 Leak Tester #239operational2025-12-30requalification-due
AST-01239 Torque Tester #240operational2025-12-31not-qualified
In-Process Controls and Pending Tests
ControlMeasuredSpecStatus
Exceptions and Deviations
ExceptionSeverityStatusDeviation
System Errorminorcloseddev-00280
System Errorminorcloseddev-01280
System ErrorminorclosedNot linked
System ErrorminorclosedNot linked
System Errorminorcloseddev-01280
System ErrorminorclosedNot linked
QA Review Checklist and Signatures
  • Step execution completeness verified with signed evidence.
  • All high-severity exceptions dispositioned or justified.
  • QC release tests reviewed and OOS investigations closed or dispositioned.
  • Final release signatory validated with segregation-of-duties check.
Release Readiness: BT-020279
Score: 63
EBR completionOpen
Exceptions closedOpen
QC approvedComplete
Deviations dispositionedOpen
Calibration compliantComplete
Training confirmedComplete

Release review blocked - critical items outstanding.

Disposition recommendation is simulated and requires QA Reviewer persona sign-off before final approval.