About this view

This batch detail page ties execution evidence, material genealogy, equipment fitness, in-process controls, and quality events into one release-focused view. Users can trace each unit operation against timestamps and investigate linked exceptions without leaving context. The panelized layout supports QA review by exception while preserving full evidence access. Next actions include closing residual issues and completing disposition-ready evidence checks.

Planned
2026-04-24 → 2026-05-04
Actual
2025-05-27 → 2025-02-14
Exceptions
12
Release Risk
medium
Step Timeline
StepStatusStartEndResult
001 Line Clearance Checkcompleted2026-07-23T06:13:00.000Z2025-11-02T04:08:00.000Z-
002 Dispensing Startcompleted2026-10-27T20:35:00.000Z2025-06-01T01:00:00.000ZCompleted as per SOP
003 API Weighingin-progress2025-07-24T23:21:00.000Z--
004 Excipient Weighingpending---
005 Granulation Startexception2026-10-20T18:32:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
006 Granulation End Weightcompleted2026-03-04T05:28:00.000Z2026-02-06T06:07:00.000ZCompleted as per SOP
007 IPC - Loss on Dryingcompleted2025-01-13T12:00:00.000Z2025-09-28T19:27:00.000Z-
008 Blending Startcompleted2026-11-15T03:45:00.000Z2025-12-24T14:37:00.000ZCompleted as per SOP
009 Blending Time Verificationin-progress2026-04-30T20:15:00.000Z--
010 IPC - Blend Uniformitypending---
011 Compression Setupexception2026-01-21T15:58:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
012 IPC - Tablet Weightcompleted2025-11-26T09:39:00.000Z2026-08-12T01:19:00.000ZCompleted as per SOP
013 IPC - Tablet Hardnesscompleted2026-08-29T10:14:00.000Z2025-08-06T12:22:00.000Z-
014 IPC - Tablet Friabilitycompleted2025-06-01T07:30:00.000Z2025-11-13T11:47:00.000ZCompleted as per SOP
015 IPC - Tablet Dissolutionin-progress2026-10-20T22:30:00.000Z--
016 Film Coating Setuppending---
017 IPC - Coating Weight Gainexception2025-03-25T01:32:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
018 IPC - Tablet Appearancecompleted2026-07-12T01:59:00.000Z2026-11-03T22:17:00.000ZCompleted as per SOP
019 Filling Setupcompleted2025-02-19T08:27:00.000Z2026-05-28T04:59:00.000Z-
020 IPC - Fill Weight Checkcompleted2026-11-07T21:46:00.000Z2026-11-02T20:46:00.000ZCompleted as per SOP
Materials Consumed and Genealogy
LotMaterialStatusGenealogy
LOT-010552Titanium Dioxide Variant 8quarantineOpen workbench
LOT-010553Polyethylene Glycol 400 Variant 8holdOpen workbench
LOT-010554Polysorbate 80 Variant 8rejectedOpen workbench
LOT-010555Mannitol Variant 8expiredOpen workbench
LOT-010556Sucrose Variant 8consumedOpen workbench
LOT-010557Trehalose Variant 8in-processOpen workbench
Equipment and Calibration
AssetStatusCalibration DueQualification
AST-01244 Blender #245cleaning-required2026-04-06not-qualified
AST-01245 Autoclave #246operational2026-09-16qualified
AST-01246 Bioreactor #247operational2025-09-11qualified
AST-01247 Centrifuge #248operational2026-02-10qualified
AST-01248 Lyophilizer #249in-calibration2025-07-10requalification-due
AST-01249 Filling Machine #250in-maintenance2025-03-23not-qualified
AST-01250 Visual Inspection System #251out-of-service2026-04-25qualified
In-Process Controls and Pending Tests
ControlMeasuredSpecStatus
Line Clearance Check10293 to 104Pass / Pending review
API Weighing10192 to 105Pass / Pending review
IPC - Loss on Drying10192 to 106Pass / Pending review
Blending Time Verification9893 to 106Pass / Pending review
IPC - Tablet Hardness10293 to 110Pass / Pending review
IPC - Tablet Dissolution10590 to 107Pass / Pending review
Filling Setup10196 to 104Pass / Pending review
Exceptions and Deviations
ExceptionSeverityStatusDeviation
Material Discrepancymajorunder-reviewdev-00093
Material Discrepancymajorunder-reviewNot linked
Material Discrepancymajorunder-reviewNot linked
Material Discrepancymajorunder-reviewdev-00093
Material Discrepancymajorunder-reviewdev-01093
Material Discrepancymajorunder-reviewdev-00593
QA Review Checklist and Signatures
  • Step execution completeness verified with signed evidence.
  • All high-severity exceptions dispositioned or justified.
  • QC release tests reviewed and OOS investigations closed or dispositioned.
  • Final release signatory validated with segregation-of-duties check.
Release Readiness: BT-020092
Score: 81
EBR completionComplete
Exceptions closedComplete
QC approvedComplete
Deviations dispositionedComplete
Calibration compliantComplete
Training confirmedComplete

Release review in progress - minor items pending.

Disposition recommendation is simulated and requires QA Reviewer persona sign-off before final approval.