About this view

This batch detail page ties execution evidence, material genealogy, equipment fitness, in-process controls, and quality events into one release-focused view. Users can trace each unit operation against timestamps and investigate linked exceptions without leaving context. The panelized layout supports QA review by exception while preserving full evidence access. Next actions include closing residual issues and completing disposition-ready evidence checks.

Planned
2026-11-02 → 2026-11-14
Actual
Pending → In progress
Exceptions
13
Release Risk
critical
Step Timeline
StepStatusStartEndResult
001 Line Clearance Checkcompleted2026-10-07T14:33:00.000Z2025-07-12T22:27:00.000Z-
002 Dispensing Startcompleted2026-11-26T10:35:00.000Z2025-03-07T00:46:00.000ZCompleted as per SOP
003 API Weighingin-progress2025-01-11T08:15:00.000Z--
004 Excipient Weighingpending---
005 Granulation Startexception2026-04-02T18:26:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
006 Granulation End Weightcompleted2025-06-11T19:46:00.000Z2026-02-12T06:31:00.000ZCompleted as per SOP
007 IPC - Loss on Dryingcompleted2026-04-17T17:16:00.000Z2026-04-09T13:07:00.000Z-
008 Blending Startcompleted2025-09-30T00:19:00.000Z2025-05-03T18:13:00.000ZCompleted as per SOP
009 Blending Time Verificationin-progress2025-09-14T07:54:00.000Z--
010 IPC - Blend Uniformitypending---
011 Compression Setupexception2025-04-03T16:06:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
012 IPC - Tablet Weightcompleted2025-02-22T09:07:00.000Z2025-05-09T12:12:00.000ZCompleted as per SOP
013 IPC - Tablet Hardnesscompleted2025-09-23T03:55:00.000Z2025-03-18T09:23:00.000Z-
014 IPC - Tablet Friabilitycompleted2025-01-13T09:21:00.000Z2026-09-07T08:11:00.000ZCompleted as per SOP
015 IPC - Tablet Dissolutionin-progress2025-02-02T18:10:00.000Z--
016 Film Coating Setuppending---
017 IPC - Coating Weight Gainexception2026-02-27T01:40:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
018 IPC - Tablet Appearancecompleted2025-08-30T16:30:00.000Z2025-10-12T04:35:00.000ZCompleted as per SOP
019 Filling Setupcompleted2026-07-15T03:10:00.000Z2026-07-26T01:02:00.000Z-
020 IPC - Fill Weight Checkcompleted2025-04-22T06:47:00.000Z2025-09-29T22:44:00.000ZCompleted as per SOP
Materials Consumed and Genealogy
LotMaterialStatusGenealogy
LOT-010801Purified Water Variant 6approvedOpen workbench
LOT-010802Ethanol 95% Variant 6approvedOpen workbench
LOT-010803Isopropyl Alcohol Variant 6approvedOpen workbench
LOT-010804Methylene Chloride Variant 6quarantineOpen workbench
LOT-010805Acetonitrile HPLC Grade Variant 6holdOpen workbench
LOT-010806Methanol HPLC Grade Variant 6rejectedOpen workbench
LOT-010807Hydrochloric Acid 37% Variant 6expiredOpen workbench
LOT-010808Sodium Hydroxide Variant 6consumedOpen workbench
LOT-010809Phosphoric Acid Variant 6in-processOpen workbench
Equipment and Calibration
AssetStatusCalibration DueQualification
AST-01134 Karl Fischer Titrator #135operational2025-06-28not-qualified
AST-01135 Dissolution Tester #136operational2026-03-20qualified
AST-01136 Hardness Tester #137in-calibration2025-03-19qualified
AST-01137 Friability Tester #138in-maintenance2025-06-23qualified
AST-01138 Particle Size Analyzer #139out-of-service2025-07-11requalification-due
AST-01139 Microscope #140cleaning-required2025-01-16not-qualified
In-Process Controls and Pending Tests
ControlMeasuredSpecStatus
Line Clearance Check10096 to 102Pass / Pending review
API Weighing10192 to 109Pass / Pending review
IPC - Loss on Drying9892 to 103Pass / Pending review
Blending Time Verification10496 to 109Pass / Pending review
IPC - Tablet Hardness10294 to 110Pass / Pending review
IPC - Tablet Dissolution10196 to 104Pass / Pending review
Filling Setup10190 to 108Pass / Pending review
Exceptions and Deviations
ExceptionSeverityStatusDeviation
Missing SignatureminorclosedNot linked
Missing SignatureminorclosedNot linked
Missing SignatureminorclosedNot linked
Missing Signatureminorcloseddev-00090
Missing SignatureminorclosedNot linked
Missing SignatureminorclosedNot linked
QA Review Checklist and Signatures
  • Step execution completeness verified with signed evidence.
  • All high-severity exceptions dispositioned or justified.
  • QC release tests reviewed and OOS investigations closed or dispositioned.
  • Final release signatory validated with segregation-of-duties check.
Release Readiness: BT-020089
Score: 85
EBR completionComplete
Exceptions closedOpen
QC approvedComplete
Deviations dispositionedComplete
Calibration compliantComplete
Training confirmedComplete

Release review in progress - minor items pending.

Disposition recommendation is simulated and requires QA Reviewer persona sign-off before final approval.