About this view

This batch detail page ties execution evidence, material genealogy, equipment fitness, in-process controls, and quality events into one release-focused view. Users can trace each unit operation against timestamps and investigate linked exceptions without leaving context. The panelized layout supports QA review by exception while preserving full evidence access. Next actions include closing residual issues and completing disposition-ready evidence checks.

Planned
2025-01-21 → 2025-01-24
Actual
2026-03-05 → In progress
Exceptions
21
Release Risk
medium
Step Timeline
StepStatusStartEndResult
001 Line Clearance Checkcompleted2025-03-31T20:48:00.000Z2025-11-09T12:26:00.000Z-
002 Dispensing Startcompleted2025-02-23T08:52:00.000Z2025-12-23T11:12:00.000ZCompleted as per SOP
003 API Weighingin-progress2026-01-17T03:49:00.000Z--
004 Excipient Weighingpending---
005 Granulation Startexception2025-03-15T04:38:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
006 Granulation End Weightcompleted2025-04-16T00:12:00.000Z2025-03-22T01:59:00.000ZCompleted as per SOP
007 IPC - Loss on Dryingcompleted2025-01-10T11:51:00.000Z2025-02-26T11:11:00.000Z-
008 Blending Startcompleted2026-02-09T05:42:00.000Z2026-01-22T02:14:00.000ZCompleted as per SOP
009 Blending Time Verificationin-progress2025-07-31T20:15:00.000Z--
010 IPC - Blend Uniformitypending---
011 Compression Setupexception2025-02-14T09:37:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
012 IPC - Tablet Weightcompleted2026-02-12T04:51:00.000Z2025-03-10T02:20:00.000ZCompleted as per SOP
013 IPC - Tablet Hardnesscompleted2026-11-05T06:29:00.000Z2026-10-31T23:41:00.000Z-
014 IPC - Tablet Friabilitycompleted2025-02-04T00:19:00.000Z2025-06-14T15:59:00.000ZCompleted as per SOP
015 IPC - Tablet Dissolutionin-progress2025-04-08T07:22:00.000Z--
016 Film Coating Setuppending---
017 IPC - Coating Weight Gainexception2026-12-18T04:17:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
018 IPC - Tablet Appearancecompleted2026-11-30T14:33:00.000Z2026-03-12T20:43:00.000ZCompleted as per SOP
019 Filling Setupcompleted2025-04-09T17:58:00.000Z2026-01-16T13:29:00.000Z-
020 IPC - Fill Weight Checkcompleted2026-09-15T14:29:00.000Z2026-05-06T02:36:00.000ZCompleted as per SOP
Materials Consumed and Genealogy
LotMaterialStatusGenealogy
LOT-010348Histidine Buffer Variant 1expiredOpen workbench
LOT-010349Sodium Chloride Variant 1consumedOpen workbench
LOT-010350Water for Injection Variant 1in-processOpen workbench
LOT-010351Purified Water Variant 1approvedOpen workbench
Equipment and Calibration
AssetStatusCalibration DueQualification
AST-01261 Isolator #262operational2025-04-05qualified
AST-01262 WFI Still #263in-calibration2025-12-30qualified
AST-01263 RO System #264in-maintenance2025-10-05requalification-due
In-Process Controls and Pending Tests
ControlMeasuredSpecStatus
Line Clearance Check10598 to 103Pass / Pending review
API Weighing10597 to 102Pass / Pending review
IPC - Loss on Drying10192 to 109Pass / Pending review
Blending Time Verification10594 to 103Pass / Pending review
IPC - Tablet Hardness10193 to 108Pass / Pending review
IPC - Tablet Dissolution10095 to 110Pass / Pending review
Filling Setup10294 to 107Pass / Pending review
Exceptions and Deviations
ExceptionSeverityStatusDeviation
System Errorminorunder-reviewNot linked
System Errorminorunder-reviewdev-01088
System Errorminorunder-reviewNot linked
System Errorminorunder-reviewNot linked
System Errorminorunder-reviewNot linked
System Errorminorunder-reviewNot linked
QA Review Checklist and Signatures
  • Step execution completeness verified with signed evidence.
  • All high-severity exceptions dispositioned or justified.
  • QC release tests reviewed and OOS investigations closed or dispositioned.
  • Final release signatory validated with segregation-of-duties check.
Release Readiness: BT-020087
Score: 70
EBR completionComplete
Exceptions closedComplete
QC approvedComplete
Deviations dispositionedOpen
Calibration compliantComplete
Training confirmedOpen

Release review blocked - critical items outstanding.

Disposition recommendation is simulated and requires QA Reviewer persona sign-off before final approval.