About this view

This batch detail page ties execution evidence, material genealogy, equipment fitness, in-process controls, and quality events into one release-focused view. Users can trace each unit operation against timestamps and investigate linked exceptions without leaving context. The panelized layout supports QA review by exception while preserving full evidence access. Next actions include closing residual issues and completing disposition-ready evidence checks.

Planned
2024-08-06 → 2024-08-16
Actual
2026-09-30 → 2024-03-03
Exceptions
7
Release Risk
low
Step Timeline
StepStatusStartEndResult
001 Line Clearance Checkcompleted2026-01-12T23:29:00.000Z2025-05-10T18:58:00.000Z-
002 Dispensing Startcompleted2026-10-23T18:16:00.000Z2025-12-22T11:38:00.000ZCompleted as per SOP
003 API Weighingin-progress2026-11-18T06:21:00.000Z--
004 Excipient Weighingpending---
005 Granulation Startexception2025-11-09T13:15:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
006 Granulation End Weightcompleted2025-05-08T05:25:00.000Z2026-06-15T20:59:00.000ZCompleted as per SOP
007 IPC - Loss on Dryingcompleted2025-06-03T09:47:00.000Z2025-12-24T21:19:00.000Z-
008 Blending Startcompleted2026-02-10T10:21:00.000Z2025-11-24T21:44:00.000ZCompleted as per SOP
009 Blending Time Verificationin-progress2026-11-22T02:08:00.000Z--
010 IPC - Blend Uniformitypending---
011 Compression Setupexception2026-01-22T21:49:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
012 IPC - Tablet Weightcompleted2026-11-18T00:06:00.000Z2026-10-21T15:51:00.000ZCompleted as per SOP
013 IPC - Tablet Hardnesscompleted2026-09-06T02:58:00.000Z2025-01-03T23:06:00.000Z-
014 IPC - Tablet Friabilitycompleted2025-10-20T09:24:00.000Z2025-01-08T14:28:00.000ZCompleted as per SOP
015 IPC - Tablet Dissolutionin-progress2025-11-14T01:44:00.000Z--
016 Film Coating Setuppending---
017 IPC - Coating Weight Gainexception2026-01-29T17:24:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
018 IPC - Tablet Appearancecompleted2026-04-04T16:54:00.000Z2025-01-30T11:33:00.000ZCompleted as per SOP
019 Filling Setupcompleted2026-07-26T23:10:00.000Z2025-03-25T04:23:00.000Z-
020 IPC - Fill Weight Checkcompleted2026-01-06T21:19:00.000Z2025-12-18T12:02:00.000ZCompleted as per SOP
Materials Consumed and Genealogy
LotMaterialStatusGenealogy
LOT-010504Methylene Chloride Variant 6approvedOpen workbench
LOT-010505Acetonitrile HPLC Grade Variant 6approvedOpen workbench
LOT-010506Methanol HPLC Grade Variant 6approvedOpen workbench
LOT-010507Hydrochloric Acid 37% Variant 6quarantineOpen workbench
LOT-010508Sodium Hydroxide Variant 6holdOpen workbench
LOT-010509Phosphoric Acid Variant 6rejectedOpen workbench
Equipment and Calibration
AssetStatusCalibration DueQualification
AST-01188 Incubator #189cleaning-required2025-04-29requalification-due
AST-01189 Autoclave Sterilizer #190operational2025-04-13not-qualified
AST-01190 Conveyor Belt #191operational2024-05-15qualified
AST-01191 Labeling Machine #192operational2025-08-01qualified
AST-01192 Cartoning Machine #193in-calibration2025-07-17qualified
AST-01193 Blister Packer #194in-maintenance2026-05-01requalification-due
AST-01194 Shrink Wrapper #195out-of-service2026-02-07not-qualified
In-Process Controls and Pending Tests
ControlMeasuredSpecStatus
Line Clearance Check10394 to 106Pass / Pending review
API Weighing10392 to 104Pass / Pending review
IPC - Loss on Drying10396 to 103Pass / Pending review
Blending Time Verification10098 to 103Pass / Pending review
IPC - Tablet Hardness10495 to 104Pass / Pending review
IPC - Tablet Dissolution10590 to 106Pass / Pending review
Filling Setup10495 to 108Pass / Pending review
Exceptions and Deviations
ExceptionSeverityStatusDeviation
Material DiscrepancyminorclosedNot linked
Material Discrepancyminorcloseddev-01085
Material DiscrepancyminorclosedNot linked
Material DiscrepancyminorclosedNot linked
Material DiscrepancyminorclosedNot linked
Material DiscrepancyminorclosedNot linked
QA Review Checklist and Signatures
  • Step execution completeness verified with signed evidence.
  • All high-severity exceptions dispositioned or justified.
  • QC release tests reviewed and OOS investigations closed or dispositioned.
  • Final release signatory validated with segregation-of-duties check.
Release Readiness: BT-020084
Score: 81
EBR completionComplete
Exceptions closedComplete
QC approvedComplete
Deviations dispositionedOpen
Calibration compliantComplete
Training confirmedComplete

Release review in progress - minor items pending.

Disposition recommendation is simulated and requires QA Reviewer persona sign-off before final approval.