About this view

This batch detail page ties execution evidence, material genealogy, equipment fitness, in-process controls, and quality events into one release-focused view. Users can trace each unit operation against timestamps and investigate linked exceptions without leaving context. The panelized layout supports QA review by exception while preserving full evidence access. Next actions include closing residual issues and completing disposition-ready evidence checks.

Planned
2025-02-14 → 2025-02-21
Actual
2024-01-09 → In progress
Exceptions
4
Release Risk
low
Step Timeline
StepStatusStartEndResult
001 Line Clearance Checkcompleted2026-08-19T19:13:00.000Z2025-05-29T06:26:00.000Z-
002 Dispensing Startcompleted2025-06-22T20:29:00.000Z2026-10-05T09:42:00.000ZCompleted as per SOP
003 API Weighingin-progress2026-04-15T15:25:00.000Z--
004 Excipient Weighingpending---
005 Granulation Startexception2025-03-14T07:41:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
006 Granulation End Weightcompleted2025-07-22T13:36:00.000Z2025-09-11T05:04:00.000ZCompleted as per SOP
007 IPC - Loss on Dryingcompleted2026-08-26T21:50:00.000Z2026-11-15T09:50:00.000Z-
008 Blending Startcompleted2026-11-10T15:25:00.000Z2025-09-03T10:29:00.000ZCompleted as per SOP
009 Blending Time Verificationin-progress2025-09-05T19:50:00.000Z--
010 IPC - Blend Uniformitypending---
011 Compression Setupexception2026-06-25T16:06:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
012 IPC - Tablet Weightcompleted2025-06-15T10:57:00.000Z2026-09-18T03:03:00.000ZCompleted as per SOP
013 IPC - Tablet Hardnesscompleted2025-05-16T06:44:00.000Z2026-06-25T13:55:00.000Z-
014 IPC - Tablet Friabilitycompleted2026-01-16T05:26:00.000Z2026-11-22T22:02:00.000ZCompleted as per SOP
015 IPC - Tablet Dissolutionin-progress2025-07-17T23:37:00.000Z--
016 Film Coating Setuppending---
017 IPC - Coating Weight Gainexception2025-06-17T21:08:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
018 IPC - Tablet Appearancecompleted2025-11-07T21:43:00.000Z2026-11-19T10:09:00.000ZCompleted as per SOP
019 Filling Setupcompleted2025-09-08T02:07:00.000Z2026-04-11T01:39:00.000Z-
020 IPC - Fill Weight Checkcompleted2025-11-03T03:10:00.000Z2025-10-21T15:55:00.000ZCompleted as per SOP
Materials Consumed and Genealogy
LotMaterialStatusGenealogy
LOT-010670Colloidal Silicon Dioxide Variant 2holdOpen workbench
LOT-010671Stearic Acid Variant 2rejectedOpen workbench
LOT-010672Titanium Dioxide Variant 2expiredOpen workbench
LOT-010673Polyethylene Glycol 400 Variant 2consumedOpen workbench
LOT-010674Polysorbate 80 Variant 2in-processOpen workbench
LOT-010675Mannitol Variant 2approvedOpen workbench
LOT-010676Sucrose Variant 2approvedOpen workbench
LOT-010677Trehalose Variant 2approvedOpen workbench
LOT-010678Histidine Buffer Variant 2quarantineOpen workbench
LOT-010679Sodium Chloride Variant 2holdOpen workbench
Equipment and Calibration
AssetStatusCalibration DueQualification
AST-01069 Autoclave Sterilizer #70cleaning-required2024-12-24not-qualified
AST-01070 Conveyor Belt #71operational2026-01-26qualified
AST-01071 Labeling Machine #72operational2025-07-27qualified
AST-01072 Cartoning Machine #73operational2024-10-01qualified
AST-01073 Blister Packer #74in-calibration2024-11-11requalification-due
AST-01074 Shrink Wrapper #75in-maintenance2026-01-18not-qualified
AST-01075 Checkweigher #76out-of-service2026-09-09qualified
In-Process Controls and Pending Tests
ControlMeasuredSpecStatus
Line Clearance Check10291 to 108Pass / Pending review
API Weighing10593 to 102Pass / Pending review
IPC - Loss on Drying9897 to 102Pass / Pending review
Blending Time Verification9995 to 110Pass / Pending review
IPC - Tablet Hardness9892 to 105Pass / Pending review
IPC - Tablet Dissolution10390 to 103Pass / Pending review
Filling Setup10197 to 105Pass / Pending review
Exceptions and Deviations
ExceptionSeverityStatusDeviation
Equipment Conflictminorunder-reviewNot linked
Equipment Conflictminorunder-reviewdev-01068
Equipment Conflictminorunder-reviewdev-00568
Equipment Conflictminorunder-reviewNot linked
Equipment Conflictminorunder-reviewNot linked
Equipment Conflictminorunder-reviewdev-00568
QA Review Checklist and Signatures
  • Step execution completeness verified with signed evidence.
  • All high-severity exceptions dispositioned or justified.
  • QC release tests reviewed and OOS investigations closed or dispositioned.
  • Final release signatory validated with segregation-of-duties check.
Release Readiness: BT-020067
Score: 75
EBR completionComplete
Exceptions closedOpen
QC approvedComplete
Deviations dispositionedComplete
Calibration compliantComplete
Training confirmedComplete

Release review in progress - minor items pending.

Disposition recommendation is simulated and requires QA Reviewer persona sign-off before final approval.