About this view

This batch detail page ties execution evidence, material genealogy, equipment fitness, in-process controls, and quality events into one release-focused view. Users can trace each unit operation against timestamps and investigate linked exceptions without leaving context. The panelized layout supports QA review by exception while preserving full evidence access. Next actions include closing residual issues and completing disposition-ready evidence checks.

Planned
2024-04-08 → 2024-04-22
Actual
2026-07-16 → In progress
Exceptions
20
Release Risk
medium
Step Timeline
StepStatusStartEndResult
001 Line Clearance Checkcompleted2025-02-05T05:39:00.000Z2025-12-21T12:38:00.000Z-
002 Dispensing Startcompleted2025-04-12T14:32:00.000Z2025-10-22T03:02:00.000ZCompleted as per SOP
003 API Weighingin-progress2025-01-03T16:22:00.000Z--
004 Excipient Weighingpending---
005 Granulation Startexception2025-01-04T09:49:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
006 Granulation End Weightcompleted2026-05-14T03:12:00.000Z2025-06-19T16:41:00.000ZCompleted as per SOP
007 IPC - Loss on Dryingcompleted2025-02-27T09:15:00.000Z2025-11-30T11:30:00.000Z-
008 Blending Startcompleted2026-09-07T03:42:00.000Z2026-07-13T05:32:00.000ZCompleted as per SOP
009 Blending Time Verificationin-progress2026-07-02T05:08:00.000Z--
010 IPC - Blend Uniformitypending---
011 Compression Setupexception2026-02-25T22:07:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
012 IPC - Tablet Weightcompleted2026-12-05T17:21:00.000Z2026-12-21T06:43:00.000ZCompleted as per SOP
013 IPC - Tablet Hardnesscompleted2026-10-23T17:22:00.000Z2025-01-05T03:35:00.000Z-
014 IPC - Tablet Friabilitycompleted2025-02-24T00:24:00.000Z2025-05-20T23:00:00.000ZCompleted as per SOP
015 IPC - Tablet Dissolutionin-progress2025-03-18T21:26:00.000Z--
016 Film Coating Setuppending---
017 IPC - Coating Weight Gainexception2025-05-21T15:35:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
018 IPC - Tablet Appearancecompleted2025-01-23T07:03:00.000Z2025-05-29T23:50:00.000ZCompleted as per SOP
019 Filling Setupcompleted2026-10-12T05:14:00.000Z2025-05-12T18:41:00.000Z-
020 IPC - Fill Weight Checkcompleted2025-03-24T02:45:00.000Z2025-07-07T02:26:00.000ZCompleted as per SOP
Materials Consumed and Genealogy
LotMaterialStatusGenealogy
LOT-010204Methylene Chloride Variant 6expiredOpen workbench
LOT-010205Acetonitrile HPLC Grade Variant 6consumedOpen workbench
LOT-010206Methanol HPLC Grade Variant 6in-processOpen workbench
LOT-010207Hydrochloric Acid 37% Variant 6approvedOpen workbench
Equipment and Calibration
AssetStatusCalibration DueQualification
AST-01008 Lyophilizer #9operational2026-08-12requalification-due
AST-01009 Filling Machine #10operational2026-08-10not-qualified
AST-01010 Visual Inspection System #11in-calibration2025-05-23qualified
AST-01011 Weighing Balance #12in-maintenance2026-05-08qualified
AST-01012 HPLC System #13out-of-service2025-02-09qualified
AST-01013 UV-Vis Spectrophotometer #14cleaning-required2025-08-09requalification-due
AST-01014 Karl Fischer Titrator #15operational2025-01-06not-qualified
AST-01015 Dissolution Tester #16operational2026-09-05qualified
In-Process Controls and Pending Tests
ControlMeasuredSpecStatus
Line Clearance Check10597 to 104Pass / Pending review
API Weighing10498 to 109Pass / Pending review
IPC - Loss on Drying10492 to 105Pass / Pending review
Blending Time Verification10090 to 103Pass / Pending review
IPC - Tablet Hardness10192 to 104Pass / Pending review
IPC - Tablet Dissolution10192 to 105Pass / Pending review
Filling Setup10596 to 105Pass / Pending review
Exceptions and Deviations
ExceptionSeverityStatusDeviation
Equipment Conflictmajorunder-reviewNot linked
Equipment Conflictmajorunder-reviewNot linked
Equipment Conflictmajorunder-reviewNot linked
Equipment Conflictmajorunder-reviewdev-00052
Equipment Conflictmajorunder-reviewNot linked
Equipment Conflictmajorunder-reviewNot linked
QA Review Checklist and Signatures
  • Step execution completeness verified with signed evidence.
  • All high-severity exceptions dispositioned or justified.
  • QC release tests reviewed and OOS investigations closed or dispositioned.
  • Final release signatory validated with segregation-of-duties check.
Release Readiness: BT-020051
Score: 91
EBR completionComplete
Exceptions closedComplete
QC approvedComplete
Deviations dispositionedComplete
Calibration compliantComplete
Training confirmedComplete

Release review complete - all criteria met.

Disposition recommendation is simulated and requires QA Reviewer persona sign-off before final approval.