About this view

This batch detail page ties execution evidence, material genealogy, equipment fitness, in-process controls, and quality events into one release-focused view. Users can trace each unit operation against timestamps and investigate linked exceptions without leaving context. The panelized layout supports QA review by exception while preserving full evidence access. Next actions include closing residual issues and completing disposition-ready evidence checks.

Planned
2025-10-30 → 2025-11-13
Actual
2026-10-28 → In progress
Exceptions
22
Release Risk
medium
Step Timeline
StepStatusStartEndResult
001 Line Clearance Checkcompleted2025-03-10T23:24:00.000Z2025-01-12T20:10:00.000Z-
002 Dispensing Startcompleted2026-09-08T22:19:00.000Z2025-11-06T01:13:00.000ZCompleted as per SOP
003 API Weighingin-progress2025-03-09T20:59:00.000Z--
004 Excipient Weighingpending---
005 Granulation Startexception2026-11-27T19:47:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
006 Granulation End Weightcompleted2026-04-27T14:46:00.000Z2026-08-01T11:59:00.000ZCompleted as per SOP
007 IPC - Loss on Dryingcompleted2026-05-08T15:34:00.000Z2026-08-02T11:11:00.000Z-
008 Blending Startcompleted2025-12-07T05:40:00.000Z2025-02-17T07:18:00.000ZCompleted as per SOP
009 Blending Time Verificationin-progress2026-11-27T01:34:00.000Z--
010 IPC - Blend Uniformitypending---
011 Compression Setupexception2025-08-17T06:10:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
012 IPC - Tablet Weightcompleted2025-11-30T12:52:00.000Z2025-05-28T04:10:00.000ZCompleted as per SOP
013 IPC - Tablet Hardnesscompleted2026-05-07T21:34:00.000Z2025-11-22T20:09:00.000Z-
014 IPC - Tablet Friabilitycompleted2026-01-22T21:03:00.000Z2026-04-19T19:52:00.000ZCompleted as per SOP
015 IPC - Tablet Dissolutionin-progress2026-02-16T22:53:00.000Z--
016 Film Coating Setuppending---
017 IPC - Coating Weight Gainexception2026-09-24T13:12:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
018 IPC - Tablet Appearancecompleted2026-06-05T16:45:00.000Z2025-05-19T04:10:00.000ZCompleted as per SOP
019 Filling Setupcompleted2026-05-26T05:51:00.000Z2025-02-07T09:50:00.000Z-
020 IPC - Fill Weight Checkcompleted2026-04-24T20:44:00.000Z2026-04-03T17:32:00.000ZCompleted as per SOP
Materials Consumed and Genealogy
LotMaterialStatusGenealogy
LOT-010100Colloidal Silicon Dioxide Variant 3approvedOpen workbench
LOT-010101Stearic Acid Variant 3approvedOpen workbench
LOT-010102Titanium Dioxide Variant 3quarantineOpen workbench
LOT-010103Polyethylene Glycol 400 Variant 3holdOpen workbench
LOT-010104Polysorbate 80 Variant 3rejectedOpen workbench
Equipment and Calibration
AssetStatusCalibration DueQualification
AST-01080 Granulator #81in-calibration2025-12-31qualified
AST-01081 Tablet Press #82in-maintenance2024-12-18qualified
AST-01082 Film Coater #83out-of-service2025-07-29qualified
AST-01083 Capsule Filler #84cleaning-required2025-04-29requalification-due
In-Process Controls and Pending Tests
ControlMeasuredSpecStatus
Line Clearance Check10295 to 106Pass / Pending review
API Weighing10297 to 107Pass / Pending review
IPC - Loss on Drying10397 to 107Pass / Pending review
Blending Time Verification10395 to 103Pass / Pending review
IPC - Tablet Hardness9896 to 109Pass / Pending review
IPC - Tablet Dissolution9897 to 103Pass / Pending review
Filling Setup10090 to 104Pass / Pending review
Exceptions and Deviations
ExceptionSeverityStatusDeviation
Material Discrepancycriticalopendev-00021
Material DiscrepancycriticalopenNot linked
Material DiscrepancycriticalopenNot linked
Material DiscrepancycriticalopenNot linked
Material DiscrepancycriticalopenNot linked
Material DiscrepancycriticalopenNot linked
QA Review Checklist and Signatures
  • Step execution completeness verified with signed evidence.
  • All high-severity exceptions dispositioned or justified.
  • QC release tests reviewed and OOS investigations closed or dispositioned.
  • Final release signatory validated with segregation-of-duties check.
Release Readiness: BT-020020
Score: 93
EBR completionComplete
Exceptions closedComplete
QC approvedComplete
Deviations dispositionedComplete
Calibration compliantComplete
Training confirmedOpen

Release review complete - all criteria met.

Disposition recommendation is simulated and requires QA Reviewer persona sign-off before final approval.