About this view

This batch detail page ties execution evidence, material genealogy, equipment fitness, in-process controls, and quality events into one release-focused view. Users can trace each unit operation against timestamps and investigate linked exceptions without leaving context. The panelized layout supports QA review by exception while preserving full evidence access. Next actions include closing residual issues and completing disposition-ready evidence checks.

Planned
2026-02-02 → 2026-02-11
Actual
2024-12-07 → In progress
Exceptions
5
Release Risk
low
Step Timeline
StepStatusStartEndResult
001 Line Clearance Checkcompleted2025-03-10T07:47:00.000Z2025-11-08T18:34:00.000Z-
002 Dispensing Startcompleted2026-07-15T12:38:00.000Z2025-07-04T02:46:00.000ZCompleted as per SOP
003 API Weighingin-progress2025-11-08T10:05:00.000Z--
004 Excipient Weighingpending---
005 Granulation Startexception2025-01-06T02:48:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
006 Granulation End Weightcompleted2025-06-19T03:39:00.000Z2025-06-07T19:07:00.000ZCompleted as per SOP
007 IPC - Loss on Dryingcompleted2026-09-20T13:49:00.000Z2025-05-21T02:16:00.000Z-
008 Blending Startcompleted2025-10-30T08:56:00.000Z2025-08-23T10:06:00.000ZCompleted as per SOP
009 Blending Time Verificationin-progress2026-07-06T12:40:00.000Z--
010 IPC - Blend Uniformitypending---
011 Compression Setupexception2026-04-16T07:36:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
012 IPC - Tablet Weightcompleted2026-10-16T23:54:00.000Z2025-03-11T16:19:00.000ZCompleted as per SOP
013 IPC - Tablet Hardnesscompleted2026-12-10T20:44:00.000Z2026-10-05T17:48:00.000Z-
014 IPC - Tablet Friabilitycompleted2025-08-05T16:13:00.000Z2026-09-27T12:05:00.000ZCompleted as per SOP
015 IPC - Tablet Dissolutionin-progress2025-04-23T14:39:00.000Z--
016 Film Coating Setuppending---
017 IPC - Coating Weight Gainexception2025-03-03T15:06:00.000Z-Value out of specification: undefined (spec: undefined-undefined)
018 IPC - Tablet Appearancecompleted2026-06-25T19:08:00.000Z2025-04-24T05:58:00.000ZCompleted as per SOP
019 Filling Setupcompleted2026-01-06T09:42:00.000Z2026-07-01T21:28:00.000Z-
020 IPC - Fill Weight Checkcompleted2025-11-13T20:11:00.000Z2025-08-09T02:26:00.000ZCompleted as per SOP
Materials Consumed and Genealogy
LotMaterialStatusGenealogy
LOT-010000Active Pharmaceutical Ingredient AapprovedOpen workbench
LOT-010001Active Pharmaceutical Ingredient BapprovedOpen workbench
LOT-010002Active Pharmaceutical Ingredient CapprovedOpen workbench
LOT-010003Microcrystalline CellulosequarantineOpen workbench
LOT-010004Lactose MonohydrateholdOpen workbench
LOT-010005Hydroxypropyl MethylcelluloserejectedOpen workbench
Equipment and Calibration
AssetStatusCalibration DueQualification
AST-01000 Granulator #1operational2025-09-25qualified
AST-01001 Tablet Press #2operational2024-08-06qualified
AST-01002 Film Coater #3operational2025-08-15qualified
AST-01003 Capsule Filler #4in-calibration2024-12-09requalification-due
AST-01004 Blender #5in-maintenance2024-05-29not-qualified
AST-01005 Autoclave #6out-of-service2025-07-22qualified
AST-01006 Bioreactor #7cleaning-required2024-12-27qualified
In-Process Controls and Pending Tests
ControlMeasuredSpecStatus
Line Clearance Check10195 to 103Pass / Pending review
API Weighing10296 to 106Pass / Pending review
IPC - Loss on Drying10496 to 102Pass / Pending review
Blending Time Verification9894 to 110Pass / Pending review
IPC - Tablet Hardness9891 to 106Pass / Pending review
IPC - Tablet Dissolution10596 to 108Pass / Pending review
Filling Setup10596 to 108Pass / Pending review
Exceptions and Deviations
ExceptionSeverityStatusDeviation
Out of SpecificationcriticalopenNot linked
Out of SpecificationcriticalopenNot linked
Out of Specificationcriticalopendev-00501
Out of Specificationcriticalopendev-00001
Out of SpecificationcriticalopenNot linked
Out of Specificationcriticalopendev-00501
QA Review Checklist and Signatures
  • Step execution completeness verified with signed evidence.
  • All high-severity exceptions dispositioned or justified.
  • QC release tests reviewed and OOS investigations closed or dispositioned.
  • Final release signatory validated with segregation-of-duties check.
Release Readiness: BT-020000
Score: 90
EBR completionComplete
Exceptions closedComplete
QC approvedComplete
Deviations dispositionedComplete
Calibration compliantComplete
Training confirmedComplete

Release review complete - all criteria met.

Disposition recommendation is simulated and requires QA Reviewer persona sign-off before final approval.